Pego Electronics (Yi Chun) Company Limited

Pego Electronics-Focus on developing and promoting IEC lab testing equipments

Manufacturer from China
Verified Supplier
7 Years
Home / Products / Test Finger Probe /

IEC61010-1 Clause 6.2.1 Annex B Figure B.1 Rigid Finger Probe Metal and Nylon Construction

Contact Now
Pego Electronics (Yi Chun) Company Limited
Visit Website
City:yichun
Province/State:jiangxi
Country/Region:china
Contact Person:MsPenny Peng
Contact Now

IEC61010-1 Clause 6.2.1 Annex B Figure B.1 Rigid Finger Probe Metal and Nylon Construction

Ask Latest Price
Video Channel
Brand Name :PEGO
Model Number :PG-TP11
Certification :Third-Lab Calibration Certificate
Place of Origin :China
MOQ :1 set
Price :USD150~USD200
Payment Terms :T/T, Western Union, MoneyGram
Delivery Time :7 working days
Packaging Details :carton
Standard :IEC61010-1
Material :metal and nylon
Force :0~50N
Type :accessability probe
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

IEC61010-1 Clause 6.2.1 Annex B Figure B.1 Rigid Finger Probe

1. Introduction

Test probe 11, commonly known as the Rigid Test Finger, is designed according to IEC61032, GB/T 16842 Figure 7, IEC60335-1 clause 22.11, EN50075 clause 8.1, IEC61010-1 clause 6.2.2 and Figure B.1, IEC60884-1 clause 10.1, AS/NZS3112 clause 3.14.12.4 and Appendix K3 requirements. It is used to test the protection of human body from touching dangerous parts, and can also be used to test the mechanical strength of the holes of the housing or the internal baffles of the housing. 0-50N and 0-75N thrust can be added, which is more convenient for tests that require force application during testing.

2. Standard

IEC61032 Protection of persons and equipment by enclosures - Probes for verification Figure 7

IEC60335-1 Household and similar electrical appliances - Safety - Part 1: General requirements Clause 22.11

EN50075 Flat non-wirable two-pole plugs, 2,5A 250V, with cord, for the connection of class II-equipment for household and similar purposes Clause 8.1

IEC61010-1 Medical electrical equipment - Part 1: General requirements for basic safety and essential performance Clause 6.2.2 and Figure B.1

IEC60884-1 Plugs and socket-outlets for household and similar purposes –Part 1: General requirements Clause 10.1, 75N

AS/NZS3112 Approval and test specification - Plugs and socket-outlets Clause 3.14.12.4 and Annex K3,50N

3. Parameters

diameter of test finger 12mm
Length of test finger 80mm
Diameter of baffle 50mm
Thickness of baffle: 5mm
Strength range 10N, 20N, 30N, 40N, 50N
Material insulating material, metal

4. Figure

IEC61010-1 Clause 6.2.1 Annex B Figure B.1 Rigid Finger Probe Metal and Nylon Construction

IEC61010-1 Clause 6.2.1 Annex B Figure B.1 Rigid Finger Probe Metal and Nylon Construction